Advancing continuous in-situ quantification of microbial contamination in environmental waters using tryptophan-like fluorescence - Sensor design and validation

Advancing continuous in-situ quantification of microbial contamination in environmental waters using tryptophan-like fluorescence - Sensor design and validation

This is a Preprint and has not been peer reviewed. This is version 1 of this Preprint.

Add a Comment

You must log in to post a comment.


Comments

There are no comments or no comments have been made public for this article.

Downloads

Download Preprint

Authors

Whitney Knopp, Joshua Klaus, Danny Wilson, Michael J Vlah, Matthew RV Ross, Evan Thomas

Abstract

Microbial contamination of recreational and source waters poses persistent public health risks, yet conventional monitoring based on laboratory culture methods provides delayed results and limited temporal resolution. These constraints hinder timely identification of short-duration contamination events and effective management of recreation advisories. This study evaluates the performance of a continuous, in-situ tryptophan-like fluorescence (TLF) monitoring system for high-frequency assessment of microbial water quality across laboratory experiments, site-specific field deployments, and a global multi-site modeling framework. Site-specific analyses employed conventional linear regression, while a machine learning approach was used to develop a global model trained across multiple deployments and evaluated using temporal holdouts.

Under controlled laboratory conditions, the system reproducibly demonstrated sub-ppb sensitivity that exceeds the stated detection limits of many commercially available TLF instruments. Field deployments in recreational surface waters showed strong agreement between sensor-derived Escherichia coli estimates and laboratory measurements obtained using the industry-standard Colilert method. Approximately 75% of linear, continuous predictions fell within the analytical uncertainty bounds of Colilert with a mean absolute percentage error of 7% in log-transformed concentration space. Binary classification at management-relevant thresholds for a deployment on the Seine in Paris achieved a balanced accuracy of greater than 90% for time-blocked test holdout data. A global model demonstrated a a mean absolute percentage error of approximately 23% in log space. Quantitative agreement was strongest at moderate to high concentrations, with increased uncertainty at low concentrations reflecting limitations of both fluorescence sensing and culture-based reference methods.

Together, these results demonstrate that continuous TLF-based measurement can complement laboratory monitoring by providing real-time screening and decision support for recreational water management. As additional deployments and training data are incorporated, the global model is expected to further improve, enhancing the scalability and operational value of continuous microbial water quality monitoring.

DOI

https://doi.org/10.31223/X5146C

Subjects

Environmental Engineering, Environmental Monitoring

Keywords

Microbial water quality, Tryptophan-like fluorescence, Continuous Monitoring, In-situ sensing, Recreational waters, fecal contamination